Skip to content

Data Requirements

This page describes the input data formats and requirements for csttool.


Supported Input Formats

csttool accepts diffusion MRI data in two formats:

Format Description
DICOM Raw scanner output; automatically converted to NIfTI
NIfTI Pre-converted .nii or .nii.gz with gradient files

NIfTI Input

Required Files

For NIfTI input, you need three files with matching base names:

mdwi.nii.gz     # 4D diffusion-weighted image
dwi.bval       # b-values (one per volume)
dwi.bvec       # b-vectors (3 × N matrix)

Gradient file extensions

csttool supports both singular (.bval, .bvec) and plural (.bvals, .bvecs) extensions. These are automatically detected.

File Specifications

File Format Description
.nii.gz 4D NIfTI Shape: (X, Y, Z, N) where N = number of volumes
.bval Space-separated text N b-values (e.g., 0 1000 1000 1000...)
.bvec Space-separated text 3 rows × N columns (gradient directions)

Example b-value File

0 1000 1000 1000 1000 2000 2000 2000

Example b-vector File

0.0  0.5774  -0.5774   0.5774  -0.5774   0.7071  -0.7071   0.0
0.0  0.5774   0.5774  -0.5774   0.5774   0.0      0.7071   0.7071
0.0  0.5774   0.5774   0.5774  -0.5774   0.7071   0.0     -0.7071

DICOM Input

For DICOM input, provide the path to the study directory:

study_folder/
├── series_001/          # T1-weighted (ignored)
├── series_002/          # DTI sequence (auto-selected)
│   ├── IM-0001.dcm
│   ├── IM-0002.dcm
│   └── ...
└── series_003/          # Another sequence

csttool will:

  1. Scan all series in the directory
  2. Analyze each for tractography suitability
  3. Auto-select the best diffusion series
  4. Convert to NIfTI with gradient files

Manual series selection

Use csttool import --series-index N to manually select a specific series.


Image Acquisition Requirements

Essential Requirements

Parameter Requirement Rationale
Modality Diffusion-weighted MRI Required for tractography
b-values At least one b=0 + one b>0 Minimum for DTI fitting
Directions ≥6 unique gradient directions Tensor estimation

For reliable CST extraction:

Parameter Recommended Notes
b-value 1000–3000 s/mm² Higher b improves angular resolution
Directions ≥30 Better fiber orientation estimation
Resolution ≤2.5 mm isotropic Finer detail in tract anatomy
FOV coverage Full brain + brainstem CST runs from cortex to brainstem

Incomplete field of view

CST extraction will fail if the scan does not cover the motor cortex through the brainstem. Ensure full craniocaudal coverage.

Gradient-table validation (bvals/bvecs)

At load, csttool validates the gradient table and fails loudly — rather than silently producing a corrupt tensor fit — on:

  • b-values that are non-finite or negative (unphysical);
  • no b=0 volume at the configured b0 threshold (no reference signal → no tensor fit);
  • DWI b-vectors that are not unit-norm (a sign of a truncated/miswritten .bvec file). b0 b-vectors may be zero.

The b0 threshold is the single default in csttool.defaults (50 s/mm²), exposed via --b0-threshold on preprocess, track, and run. One execution uses one threshold throughout: it builds the gradient table, and the resulting gtab.b0s_mask is what brain masking and Patch2Self read, so no stage can disagree about which volumes are b0.

DICOM b-vector reorientation

The dicom2nifti fallback converter reorients the image to a standard orientation but does not reorient the b-vectors, which would leave the gradients in the scanner's voxel space and the image in a different one — a silent gradient flip that corrupts the tensor fit. csttool converts in the native (scanner) voxel space and reorients both image and b-vectors to RAS+ together, matching the dcm2niix primary path. The primary dcm2niix path is unaffected. (AU21)


Coordinate Space Requirements

Critical: World Space (mm) Required

Tractogram streamlines must be in world coordinates (millimeters), not voxel indices. This is a common source of errors when using tractograms from external sources.

Property Correct (mm) Incorrect (voxels)
Coordinate range -100 to +100 0 to 256
Typical values -80.5, 45.2, 62.0 45, 120, 78
Negative coordinates Common (RAS space) Rare or absent

Automatic Validation

csttool automatically validates coordinate systems when running extraction. If your tractogram is in voxel space, you will see an error like:

Error: Coordinate validation failed. This can lead to incorrect results.
Errors: Coordinate space mismatch detected: values suggest voxel indices, not mm

The validator also asserts affine equality between the tractogram and the FA map (translation ≤ 1.0 mm, rotation/scale ≤ 1e-3), not just bounding-box overlap — a tractogram and FA map in mismatched coordinate spaces can have overlapping world bounds and would otherwise pass, then yield anatomically-plausible-but-wrong extraction. For .trk this is checked explicitly; for headerless formats like .tck that carry no spatial header, csttool warns that the affine could not be asserted (verify the tractogram is in the same RASMM space as the FA map). (AU22)

Converting Voxel to World Coordinates

If your tractogram is in voxel space, convert it before using csttool:

import nibabel as nib
from dipy.io.streamline import load_tractogram, save_tractogram
from dipy.io.stateful_tractogram import Space

# Load with reference image
ref_img = nib.load("fa.nii.gz")
sft = load_tractogram("tractogram.trk", ref_img, to_space=Space.VOX)

# Convert to world coordinates
sft.to_rasmm()

# Save converted tractogram
save_tractogram(sft, "tractogram_rasmm.trk")

Skipping validation (not recommended)

You can bypass coordinate validation with --skip-coordinate-validation, but this is strongly discouraged as it can produce anatomically plausible but incorrect results.


Validating Your Data

Run csttool doctor to verify your environment, then:

# Check DICOM study
csttool import --dicom /path/to/study --out /path/to/output

# Check NIfTI files
csttool import --nifti /path/to/dwi.nii.gz --out /path/to/output

The import step will report:

  • Number of volumes
  • b-values present
  • Number of gradient directions
  • Any warnings about data quality

For testing or learning, use these publicly available diffusion MRI datasets:

Dataset b-value Directions Access
HCP Young Adult 1000/2000/3000 90×3 shells Registration required
Brainlife Open Datasets Various Various Free
OpenNeuro dMRI Various Various Free

Note that registration may be required.


Next Steps